Models UMPX-12
Output
Capacity 2700W/3000VA
Output Voltage 200V/220V/230V/240V (Selectable)
Maximum Output Current 9.0 Amp (120V Input) / 12.5 Amp (200V+ Input)
Output Peak Current (<250mS) 40 Amp
Maximum Continuous Load 2700W
Maximum Peak Load 3500W (Tested Under 240Vac Input)
Voltage Regulation ±2% of selected output voltage
Output Frequency 50Hz or 60Hz (selectable)
Output Frequency Synchronization 60±0.01Hz or 50±0.01Hz (independent of input frequency)
Crest Factor 3:1
Voltage Waveform Sine Wave
Total Harmonic Distortion (Resistive Load) <2%
Total Harmonic Distortion (Reactive Load) <3%
Standby Power 27W
Output EMI Filter 150Khz - 30Mhz
Output RFI Filter 30Mhz - 1000Mhz
Clamp Level 400V Peak
Efficiency (Input to Output) >87%
Output Connection From Mains
Ground Input and Output Ground are Connected
Neutral Input and Output Neutral Connected (after EMC inductor )\nIsolation Transformer is not required
Input
Nominal Voltage 120V/240V
Input Voltage Range 90Vac ~ 285Vac
Input Current 20 Amp
Input Frequency Range 45Hz - 70Hz
Input Neutral Auto Detect and Correct No
Wall-Outlet Type Required Includes 8 Input Plug Types
Phase Single
Noise Filtering Full-Time EMI/RFI Filtering
Input EMI Filter 150Khz -30Mhz (class A)
Input RFI Filter 30Mhz - 1000Mhz (class A)
Overcurrent Protection (Input) By Re-Settable; Overcurrent Protector
Power Factor ≧ 0.98
Switch-On Surge (In-Rush Current) <100A, 3mS
Voltage Interruption Ride Through 10mS
Protection
Overcurrent Protection (Output) Overload Alarm Level: 100% ~ 129% (alarm after 1 minute delay, shutdown after 1 minute alarm);\nOverload Shutdown Level: 130% (shutdown after 2 second delay)
Short-Circuit Protection Pulsating Type, 37A Peak; Auto-Restart time: 30 seconds
Over-Temperature Protection When the temperature inside is over 76℃, the LCD will show the Over-Temperature Symbol.\nIf the temperature continues rising to 85℃, the buzzer alert for high temperature is activated and the CPU will shut down the output voltage. The CPU will resume output voltage automatically once the temperature drops to 75℃ or lower.\n
Indicators and Alarms
LCD Display Displays Input Voltage, Output Voltage, Output Frequency, Temperature, Load Level. Selectable Output Voltage and Output Frequency
Indicator - Load Level LCD Displays Current Usage Level of Total Available Capacity
Indicator - Overload LCD Shows Overload Symbol
Indicator - Over-Temperature LCD Shows Over-Temperature Symbol
Audible Alarms Overload Alarm, Short-Circuit Alarm, Over-Temperature Alarm
Audible Alarm - Overload Continuous Alarm
Audible Alarm - Short-Circuit Every other 2 seconds, 32 beeps in 2 seconds
Audible Alarm - Over-Temperature Every other 2 seconds, 32 beeps in 2 seconds
Environmental and Safety
Sealed Solid-State Electronics No
Operating Temperature Up to 1500 meters: 0℃ to 40℃ (32℉ to 104℉)
Transit/Storage Temp -15℃ to 55℃ (5℉ to 131℉)
Relative Humidity 5 – 95% Non-Condensing
Operating Altitude 0 ~ 3000 Meters
Moisture Sensitivity Internal Fan
Audible Noise ≦45 dBA (at 1 meter from surface of unit)
Safety Markings CE & BSMI
Cooling
Cooling Method Forced Air Cooling by Internal Fan
Natural Ventilation Cooling No
Internal Fans Internal fan will run at low speed continuously when the temperature inside is low. Fan speed increases as temperature rises. When internal temperature is over 60° C, the internal fan runs at full speed
External Emergency Cooling Fan Yes
Physical
Product Dimensions (L) in 17
Product Dimensions (W) in 10
Product Dimensions (H) in 4
Product Dimensions (L) cm 43
Product Dimensions (W) cm 25
Product Dimensions (H) cm 10
Product Weight (lbs) 15
Product Weight (kgs) 6.8
Carton Dimensions (L) in 25
Carton Dimensions (W) in 14
Carton Dimensions (H) in 20
Carton Dimensions (L) cm 63
Carton Dimensions (W) cm 36
Carton Dimensions (H) cm 51
Shipping Weight (lbs) 45
Shipping Weight (kgs) 20.4
Warranty, Quality Control, and International Approvals
Warranty 2 Years, Full Replacement
Quality Control Standard ISO9001
UL-Ulus Not Applicable
UL 1012 Not Applicable
UL-cUL Not Applicable
DEMKO-CB Not Applicable
TUV/SUD-CB Not Applicable
FCC Part 15 Not Applicable
EMC Not Applicable
Other
Standard Accessories 8 Input Power Cord Types: A, B, 8303, NEMA 5-20P, NEMA 6-20P, C/F/E, G, N\nC-19 Connecting Cord\nHard Travel Case
Wall Mountable No
Appliance Mountable No
Compatibility
Output Compatibility with UPS Yes
AC Input Generator Compatible Yes