MPX-21U Portable Step Down Voltage Frequency Converter Specification Sheet
By PowerXchanger
Portable STEP-DOWN Voltage and Frequency Converter Specification | ||||||||
Model | MPX-21U | |||||||
Output | ||||||||
Output Voltage | 100V / 110V / 115V / 120V (Selectable) | |||||||
Output Current-Amps @60Hz |
|
|||||||
@Input Voltage |
|
|||||||
OUTPUT PEAK CURRENT (<250mS) | 67 Amp Max | |||||||
Voltage Regulation | ±2% of selected output voltage | |||||||
Output Frequency (auto-sync to mains) | 60Hz / 50Hz (Selectable) | |||||||
Crest Factor | 3:1 | |||||||
Voltage Waveform | Sine Wave | |||||||
Output Distortion (Resistive Load) | <2% | |||||||
Output Distortion (Reactive Load) | <3% | |||||||
Non-Linear Peak Current for 30 sec. | 42A | |||||||
Standby Power | 27W | |||||||
Total Harmonic Distortion | <3% (at full resistive load) | |||||||
Output EMI Filter | 150Khz - 30Mhz | |||||||
Protection | ||||||||
Over load Protection | 100%~129% for 60 seconds delay, then alarm ; alarm for 60 seconds, then shutdown o/p; > 130%, alarm for 2 seconds, then shutdown o/p; |
|||||||
Short-Circuit Protection | Output Protected from Short Circuit by Pulsating Type Auto-Restart Time: 30 Seconds | |||||||
Peak Voltage Protection | 200V PEAK (Clamp Level) | |||||||
Input | ||||||||
Voltage Range | 90Vac ~ 285Vac | |||||||
Maximum Continuous Load | 2340W | |||||||
Maximum Peak Load | 3000W (Tested Under 240Vac Input) | |||||||
Input Current | 20 Amp | |||||||
Input Frequency Range | 45Hz ~ 70Hz | |||||||
Phase | Single | |||||||
Noise Filtering | Full-Time EMI/RFI Filtering | |||||||
Over Current Protection | By Re-Settable Over Current Protector | |||||||
Power Factor | ≧0.98 | |||||||
Audible Alarm | Over load alarm, Short-circuit alarm, Thermal alarm | |||||||
Inrush Surge Capacity | <100A, 3mS | |||||||
Voltage Interruption Ride Through | 10mS | |||||||
Efficiency | ||||||||
Efficiency (Full Load) | Up to 90% | |||||||
Output Connection from Mains | ||||||||
Ground | Input and Output Ground Connected | |||||||
Neutral | Input and Output Neutral Connected (after EMC inductor ) Isolation Transformer is not required |
|||||||
Indicators | ||||||||
LCD Control Panel | Displays Input Voltage, Output Voltage, Output Frequency, Temperature, Load Level Selectable Output Voltage and Output Frequency |
|||||||
Output Compatibility | ||||||||
Output Compatibility with UPS | Yes | |||||||
Environmental and Safety | ||||||||
Operating Temperature | Up to 1500 meters: 0℃ to 40℃ (32℉ to 104℉) | |||||||
Transit/storage Temp. | -15℃ to 55℃ (5℉ to 131℉) | |||||||
Relative Humidity | 5 – 95% Non-Condensing | |||||||
Operating Altitude | 0 ~ 3000 Meters | |||||||
Moisture Sensitivity | Internal Fan | |||||||
Audible Noise | ≦45 dBA (at 1 meter from surface of unit) | |||||||
Cooling | ||||||||
External Cooling Fan Control | Forced air cooling by internal fan | |||||||
Physical (CONVERTER ONLY) | ||||||||
Dimensions W×D×H | 43.0 x 25.0 x 10.0 cm 17.0 x 10.0 x 4.0 in |
|||||||
Unit Weight | 6.8 kg 15 lbs |
|||||||
Physical (BRIEFCASE & CONVERTER) | ||||||||
Dimensions W×D×H | 49.3 x 39.3 x 15.6 cm 19.5 x 15.0 x 6.2 in |
|||||||
Unit Weight | 14.0 kg 31 lbs |
|||||||
Standard Accessories | ||||||||
Input Power Cords | TYPE A TYPE B TYPE 8303 (JIS-C JAPAN) TYPE C/F/E TYPE G TYPE H TYPE I TYPE J TYPE L TYPE M/D TYPE N |
|||||||
Connecting Cord | IEC C-19 Connecting Cord | |||||||
Others | ||||||||
Warranty | 2 Years, Full Replacement | |||||||
Quality Control Standard | ISO9001 | |||||||
Approvals and Safety Markings | CE |